Add to Cart
Cat 6 Cable, Cat 6 Network Cable, Cat 6 Ethernet Cable, FTP Cat 6 Cable Application
TC's U/FTP-11 series, indoor Cat 6 shielded cabling system, has test frequency up to 350MHZ, higher than other Cat 6 cables with industry standard of 250MHz.
In the meantime, it supports 5G Base-T applications and Power Over Ethernet (POE/POE+).
Product Features
The shielded structure is designed for the best ANEXT performance and 5G Base-T applications, especially useful in some harsh electromagnetic environments where high-speed and stable cable transmission is required.
At the same time, it acts on the requirements for structured cabling in new buildings.
Application Standards
TIA/EIA568-C.2
Technical Details
Transmission Performance | Cat.6 | TC | |||||
Frequency (MHz) | 4 | 31.25 | 62.5 | 100 | 200 | 250 | 350 |
IL Attenuation (dB/100M) | 3.3 | 9.3 | 13.2 | 16.7 | 22.3 | 25.1 | 30.8 |
Near End Crosstalk Attenuation (NEXT, dB) | 94.1 | 76.1 | 78.7 | 77.4 | 70.2 | 68 | 68.3 |
NEXT Power and PS NEXT (dB) | 86.4 | 70.5 | 69.5 | 58 | 49.7 | 52.8 | 46.8 |
Equal Level Far-end Crosstalk Attenuation (ACR-F, dB) | 99.4 | 94.5 | 75.7 | 66.4 | 52.7 | 51.6 | 45.2 |
ACR-F Power and PS ACR-F (dB) | 84.6 | 73.8 | 58.2 | 58.9 | 44 | 44 | 40 |
Return Loss (RL, dB) | 40.8 | 43.4 | 33.9 | 42.6 | 30 | 21.8 | 18.8 |
Notes: The values reflected in the table above are typically measured, in accordance with IEC 61156-9.
Physical Specifications | |
Conductor Size (nominal value) | 4×2×0.57 (AWG23) |
Outer Diameter of Cable (nominal value) | 8.0mm |
Weight (305m, with package, nominal value) | 17kg |
Electrical Properties | |
Transverse Conversion Loss (TCL) | ≥ 55dB-20×lgf (100-2000MHz) |
Delay Skew | 25ns/100m |
NVP | 69% |
Power Over Ethernet (POE) | Enhanced Power Over Ethernet under IEEE 802.3at |
Mechanical Properties | |
Anti-Extrusion Capacity | 1000N/10cm |
Anti-Shock Capacity | ≥ 10 times |
Installation Temperature Range | -0℃ ~+40℃ |
Working Temperature Range | -20℃ ~+75℃ |
Flammability (LSZH) | |
Flame Resistance (of single wire) | GB/T 18380.12 (IEC 60332-1-2) |
Flame Resistance (of bunched wires) | GB/T 18380.35 (IEC 60332-3-24) |
Smoke Density | GB/T 17651 (IEC 61034-1/-2) |
Hazardous Halogen Gas | GB/T 17650.1/.2 (IEC 60754-1/-2) |